Cable materials, conversion and conductor taping.+44 (0)161 740 9503
CBZSD / LONGITUDINAL WATER BLOCKING

Double-sided semi-conductive
water-blocking tape.

Covered swellable laminate for power cable interfaces requiring semi-conductivity.

CBZSD / SEMI-CONDUCTIVEBlack double-sided semi-conductive water-blocking tapeBLACK SEMI-CONDUCTIVE NONWOVEN
0.25–0.50 mmNominal thickness
100–170 g/m²Nominal mass
10–18 mmMin. swelling after 3 min
Semi-conductiveElectrical type
THE MATERIAL

Material construction.

Semi-conductive polyester nonwoven fabric with polyacrylate swelling powder and corrosion inhibitor.

Polyacrylate powder absorbs incoming water and swells into a gel, helping close internal water paths after sheath damage. The nonwoven wrap also provides bedding and separation. The semi-conductive carrier is used where the cable design requires a conductive interface.

01Swellable barrier

Absorbs incoming water to limit longitudinal movement.

02Covered laminate

Covering helps retain swelling powder during handling.

03Conductive interface

Specified surface resistance of ≤1500 Ω.

MATERIAL PROPERTIES

Technical specification.

Download datasheet (PDF)
Select grade
SELECTED GRADECBZSD-30
THICKNESS0.30 ±0.03 mm
MASS PER UNIT AREA110 ±10 g/m²
Enquire about this grade
Double-sided semi-conductive water-blocking tape — grade comparison
PropertyUnitCBZSD-30CBZSD-35CBZSD-40CBZSD-50CBZSD-25CBZSD-35NCBZSD-40NCBZSD-50N
Thicknessmm0.30 ±0.030.35 ±0.030.40 ±0.030.50 ±0.030.25 ±0.030.35 ±0.030.40 ±0.030.50 ±0.03
Mass per unit areag/m²110 ±10120 ±10130 ±10160 ±10100 ±10130 ±10140 ±10170 ±10
Minimum tensile strengthN/cm≥30≥35≥40≥50≥25≥35≥40≥50
Minimum elongation%≥12≥12≥12≥12≥12≥12≥12≥12
Minimum swelling after 1 minmm≥8≥9≥10≥12≥7≥12≥12≥13
Minimum swelling after 3 minmm≥12≥13≥14≥16≥10≥15≥16≥18
Short-term thermal stability°C230230230230230230230230
Long-term thermal stability°C9090909090909090
Maximum moisture content%≤9≤9≤9≤9≤9≤9≤9≤9
Surface resistanceΩ≤1500≤1500≤1500≤1500≤1500≤1500≤1500≤1500
Volume resistivityΩ·cm<1 × 10⁶<1 × 10⁶<1 × 10⁶<1 × 10⁶<1 × 10⁶<1 × 10⁶<1 × 10⁶<1 × 10⁶

Thermal values describe material stability, not a finished-cable temperature rating. Thickness: ISO 9073-2; tensile / elongation: ISO 9073-3; swelling: GB 450; moisture: ISO 287. Electrical properties: GB 3048. Short-term stability: Q/TR.J02.01-2000; long-term stability: IEC 216-1990.

MATERIAL SELECTION

Choosing the right construction.

Choose double-sided laminate when a covered structure and bedding are priorities. Single-sided grades suit interfaces where one active face is sufficient; compare thickness, swelling and handling. Use semi-conductive grades only where the electrical design requires them.

Related water-blocking materials.

Tape wraps broader cable surfaces; yarn targets internal gaps. A combined system can address both.

SUPPLY OPTIONS

Specified for your equipment.

Specify grade, slit width, core ID, roll diameter and pad or spool format. Other grades can be stocked to agreed customer demand.

Download datasheet (PDF)

Winding format
Pads and spools
To suit the application equipment
Slit widths and dimensions
To specification
Confirm core ID and maximum roll diameter

Application and processing.

Select overlap, tension and swelling allowance to suit the gap and cable design. Validate the complete cable for pressure, water chemistry and temperature. Salt-water duties need specific qualification.

Store sealed, clean and dry. Product imagery is representative.

CONTACT CTUK

Discuss your
requirements.

Send your material grade, dimensions and quantity.
Include pad or spool details using our enquiry form.