Cable materials, conversion and conductor taping.+44 (0)161 740 9503
PET23 / PET36 / PET50

PET polyester
film tape.

Clear polyester film for cable core binding, layer separation and electrical insulation.

PET23 / PET36 / PET50PET Polyester Film Tape pad rollBIAXIALLY ORIENTED / CLEAR UNCOATED PET
23 / 36 / 50 µmFilm thicknesses
Clear PETUncoated film
Pads & spoolsSupply formats
Manchester stockFast conversion
THE MATERIAL

Material construction.

Biaxially oriented, uncoated transparent polyester film. PET provides a smooth, electrically insulating wrap with little addition to cable diameter. Strength and flexibility support controlled taping; low moisture absorption and chemical resistance suit a wide range of cable constructions.

01Biaxially oriented PET

Strong, flexible polyester film

02Uncoated surface

Clear, smooth and non-adhesive

03Three film thicknesses

23, 36 and 50 µm

MATERIAL PROPERTIES

Technical specification.

Download full datasheet
Select grade
SELECTED GRADEPET23
THICKNESS23 µm
AREA YIELD31.1 m²/kg
Enquire about this grade
PET Polyester Film Tape — comparison by grade
PropertyUnitPET23PET36PET50
Nominal thicknessµm233650
Yieldm²/kg31.119.914.3
Tensile strength — MDkg/cm²210020001900
Tensile strength — TDkg/cm²220021002000
Elongation at break — MD%140150170
Elongation at break — TD%135145150
Heat shrinkage — MD*%1.61.61.6
Heat shrinkage — TD*%0.20.20.2
Coefficient of friction — static–0.400.420.42
Coefficient of friction — dynamic–0.350.320.32
Surface tension — plain sidedyne/cm424242
Haze%3.04.24.2
Light transmission%888888
Breakdown voltagekV6911

Typical values are guidance, not guaranteed specifications. MD = machine direction; TD = transverse direction. *Heat shrinkage at 150 °C for 30 minutes. Friction values refer to side A / side B. Source units are retained; test methods and tolerances were not specified.

Uncoated PET is non-adhesive and does not provide metallic screening, waterblocking or mica-type fire protection.

STOCK & CONVERSION

Stocked for flexible supply.

Master rolls held in Manchester support fast slitting and spooling to your required widths and winding formats, with smaller minimum order quantities.

Choose pads or traverse spools to suit your line. Custom slit widths, sizes and winding arrangements are available on request.

Pad slit widths
PET23: 10–900 mm
PET36 / PET50: 8–900 mm
Spool slit widths
PET23: 10–60 mm
PET36 / PET50: 5–60 mm
Core IDs
Pads: 76 or 152 mm
Spools: 76 mm
Maximum OD
Pads: 550 mm
Spools: 300 mm
Spool core width
100–350 mm
APPLICATION GUIDANCE

Selection and processing.

Select the lowest thickness that meets the required binding, separation and electrical performance. PET23 provides the highest area yield; PET36 and PET50 offer greater film thickness and higher typical breakdown voltage. Confirm suitability in the complete cable and actual processing conditions.

Validate your cable construction.

Match slit width, overlap and tension to the core diameter and equipment. Confirm flat wrapping and stability through extrusion. Breakdown voltage is not a cable working-voltage rating; the shrinkage test temperature is not a continuous-service rating.

CONTACT CTUK

Discuss your
requirements.

Send your material grade, dimensions and quantity.
Include pad or spool details using our enquiry form.