Cable materials, conversion and conductor taping.+44 (0)161 740 9503
FRMICA FP / COATED GLASS

FRMICA FP
coated mica tape.

Coated mica tape for fire-resistant cables, with a backing designed to reduce glass-fibre fraying during taping.

FRMICA FP / COATED GLASSFRMICA FP coated mica tape pad showing bronze mica and white coated backingINORGANIC COATED GLASS BACKING
0.13 / 0.16 mmNominal thickness
5–1000 mmAvailable widths
>3.0 kV/layerDielectric strength, FP90G28
950–1050 °CTemperature rating
THE CONSTRUCTION

Coated backing.
Cleaner processing.

High-quality calcined phlogopite mica paper, non-alkaline glass fabric and high-temperature resistant silicone resin, with an inorganic coating over the glass backing. The white, paper-like coating helps contain fibres and reduce fraying, mica flaking and sticking during winding.

01Calcined phlogopite mica paper

Bronze mica face providing a heat-resistant dielectric barrier

02Silicone resin bond / impregnation

High-temperature resistant bonding

03Non-alkaline glass fabric

Mechanical reinforcement

04Inorganic coating on the glass face

White, paper-like reverse that helps contain glass fibres

PHYSICAL & ELECTRICAL PROPERTIES

Technical specification.

Download full datasheet
Select grade
SELECTED GRADEFP90G28
TOTAL SUBSTANCE180 ±15 g/m²
DIELECTRIC STRENGTH>3.0 kV/layer
Enquire about this grade
FRMICA FP coated mica tape — specification by grade
PropertyUnitFP90G28FP120G28
Nominal thicknessmm0.130 ±0.020.160 ±0.02
Total substanceg/m²180 ±15215 ±15
Mica contentg/m²90 ±5120 ±5
Tensile strengthN/cm>80>120
Dielectric strengthkV/layer>3.0>3.0

Values from the CTUK technical datasheet. Discuss your cable construction and processing requirements with our team.

SUPPLY OPTIONS

Widths and winding formats.

Mica tape is available as pads, traverse-wound spools or step-wound spools, with custom slit widths and winding dimensions. Supply can be arranged from Manchester or directly from our manufacturing partners to suit your order.

Discuss cable-construction optimisation
Width range
5–1000 mm
Core internal diameters
76 mm
Winding
Pads, traverse-wound spools and step-wound spools.
FIRE PERFORMANCE

Standards & application.

For cable constructions targeting IEC 60331, GB/T 19216.31, BS 6387, EN 50200 and AS/NZS 3013. Temperature rating: 950–1050 °C. This temperature rating does not guarantee finished-cable performance. Physical and electrical properties are specified against IEC 60371-2.

Performance depends on the complete cable.

Fire-test performance depends on the tape grade, layers, overlap and complete cable construction. Confirm any change through finished-cable testing.

CONTACT CTUK

Discuss your
requirements.

Send your material grade, dimensions and quantity.
Include pad or spool details using our enquiry form.